V-Sorb 4800P researched from Gold APP
Instruments experts for surface area and pore size determination with
using of static volumetric principle. Multi pioneered techs heighten accuracy
and consistence of results, enhance measurement stability, all these lead to a
leading level among world technology. It designed from the user
perspective and equipped with fully automated operation, user-friendly
interface makes it easy to learn, imported accessories assure stability and
prolong life. Perfect design, sophisticated production and strict testing
guarantee to meet customers’ real demands. The high cost performance of V-Sorb
4800P easily ensure your investment profits and flexible equipped peripheral
can satisfy different users’ requests.
V-Sorb 4800P specific surface area and pore size analyzer parameters
Analysis Method: static volumetric nitrogen adsorption
Versatility: Adsorption and desorption isotherms, Single and multi-point
BET surface area analysis, T-plot external surface area, True density analysis,
BJH pore size, BJH total pore volume and porosity, T-plot micropore analysis,
MP micropore, Langmuir surface area, Horvath-Kawazoe (HK) micropore,
Saito-Foley (SF) micropore, Dubinin-Astakhov (DA) micropore,
Dubinin-Radushkevich (DR) micropore, carbon black (STSA) etc.
Measuring Ranges: 0.01m2/g to no known upper limit (surface
area); 0.35 to 500nm (pore size)
Accuracy: repeatability errors ≤1%
Vacuum System: V-Sorb unique monolithic manifolds and
electromagnetically operated valve control system, greatly reduce the dead
volume; improve the adsorbate micro-change sensitivity; enhance pore size
distribution analysis resolution; decrease connecting points; strengthen
sealing performance and prolonged instrument life
Coolant Level Prober: V-Sorb original coolant level control system with
temperature probe, ensure the coolant level unchanged when compares with sample
cells in the whole analysis process, completely eliminate the analysis errors
caused by dead volume change
Control System: programmable controller electromagnetically operated
valve system with high integration and strong anti-interference ability, enhance
instrument’s stability
Sample Ports: four samples’ analyzing and four samples’ degassing
concurrently
Pressure Measurement: imported sectional measuring dual pressure transducer,
notably improve the measuring accuracy at low P/Po point, 0-1000Torr
(0-133Kpa), 0-10Torr (0-1.33Kpa)
Transducer Accuracy: imported silicon thin film pressure transducer, accuracy
can reach 0.1% of real reading, better than 0.1% of F.S.(full-scale), far
accurate than Pirani resistance vacuum gauge(general error is 10%-15%)
Partial Pressure: P/Po controllable accuracy range is 5x10-6-0.998
Ultimate Vacuum: 4x10-2Pa (3x10-4Torr)
Vacuum Pump: built-in bipolar vacuum pump controlled by patented
software which can auto control pump’s start/stop
Adsorbate Gas: high purity nitrogen (≥99.999%), Ar, Kr, CO2, CO, C4H10
etc. non-corrosive gases are optional
Data Acquisition: high-precision and high integration data acquisition
modules, minimal error, strong anti-interference ability
Data Reduction: Windows®-based independent developed Gold APP softwareTM,
perfect versatility, produced full featured and multi-model reports
Specifications: Height 22.05 inches (56cm)* Width 20.87 inches (53cm)*Depth
23.62 inches (60cm); 132
pound (60kg)
V-Sorb 4800P specific surface area and pore size analyzer features
A: Vacuum System
1. Unique integral manifolds system, decrease connecting
points apparently, reduce leak rate, improve ultimate vacuum.
2. Modularity design can configure as customer requests,
benefits future functions extension and instrument maintenance.
3. Germany
imported bipolar vacuum pump, low noise, stable working, oil-return prevention;
ultimate vacuum can reach 4x10-2Pa (3x10-4Torr).
B: Control System
1. Industry used programmable controller
electromagnetically operated valve system, strong anti-interference ability,
convenient for installation and uninstallation.
2. Separated analysis and treatment manifolds can prevent
foreign matter to contaminate manifolds in sample treatment.
C. Measures for Improving
Accuracy
1. Imported silicon thin film capacitive pressure transducer,
accuracy can reach 0.1% of real reading, better than 0.1% of F.S. (full-scale).
2. 0-10Torr (optional) and 0-1000Torr dual pressure transducers,
sectional measurement in pressure range can reduce errors in low vacuum,
0-10Torr silicon thin film transducer is highly accurate than Pirani resistance
vacuum gauge (general error is 10%-15%).
3. Unique monolithic manifolds system, decrease connecting
points and reduce leak rate apparently.
4. Original stepping coolant level control system, ensure
the coolant level unchanged when compares with sample cells in the whole
analysis process, completely eliminate the analysis errors caused by dead
volume change.
5. Pioneered gas outlet and inlet control system can
efficiently prevent sample splash in evacuation and gas inlet process,
guarantee clean manifolds and sample weight unchanged, avoid zero and liner
drifting caused by transducer’s macro-change.
D. Data Acquisition and
Reduction
1. High precision and integration data acquisition module
is easy to connect, minimal errors and strong anti-interference ability;
standard 485 communication mode is good for analyzer’s applications extension
and interconnection, can also conveniently switched to RS232 and USB modes.
2. Multi calculating methods for data reduction provides
all-round sample analysis options; powerful data archiving and searching system
helps a lot for data management.
V-Sorb 4800P specific surface area and pore size analyzer application
1. Super micro powder, nanomaterials, particle and fiber
shaped specific surface area analysis.
2. Product quality control for powder materials related
corporations.
3. Research institutes, universities for BET theory
teaching.
4. Full cells, catalysts, additives, adsorbent, ceramics,
magnetic materials, energy storage materials etc.
5. Other researches concern surface area performance.
Contact info:
Email:
sales@jinaipu.com
Tel.: 0086-10-82133318 Ext.810
Fax: 0086-10-82118197
Mobile: 0086-18210009838
IMs:
Skype: Gold-APP-Instruments
bet surface area
bet surface analyzer, bet surface area
principle, bet surface area theory, bet surface area measurements, bet surface
area analyzer india, bet surface area instrument, bet surface area pdf, bet
surface area price, pycnometer, multipycnometer
BJH pore size
BJH pore size, Bjh pore size distribution, Bjh
pore size distribution wiki, Bjh pore size distribution equation, Bjh pore size
distribution calculation, Bjh pore diameter, Bjh pore size distribution
analysis, Bjh pore size model, Bjh pore size theory, pycnometer,
multipycnometer,
Langmuir
Langmuir, Langmuir isotherm, Langmuir
adsorption, Langmuir boldgett, Langmuir circulation, Langmuir Hinshelwood, Langmuir
waves, Langmuir isotherm derivation, pycnometer, multipycnometer,
Langmuir surface
Langmuir surface, Langmuir surface area, Langmuir
surface area definition, Langmuir surface balance, Langmuir surface chemistry, Langmuir
surface coverage, Langmuir surface tension, Langmuir surface pressure, Langmuir
surface area calculation, Langmuir surface adsorption, pycnometer,
multipycnometer
t-plot
t-plot, t-plot method, t-plot micropore
volume, t-plot surface area, t-plot deboer, t-plot micropore, t-plot harkins
jura, t plot bet, t plot adsorption, t plot external surface area, pycnometer,
multipycnometer
surface area and pore
size
surface area and pore size analyzer, surface
area and pore size, surface area and pore texture of catalysts, surface area
and pore volume, surface area and pore size distribution, surface area and pore
size analysis, surface area and pore size analysis, surface area and pore size
by gas sorption, surface area analysis
and pore size measurement, pycnometer, multipycnometer
pore size distribution
pore size distribution, pore size
distribution index, pore size distribution calculation, pore size distribution
measurement, pore size distribution soil, pore size distribution definition,
pore size distribution analysis, pore size distribution curve, pore size
distribution bet, pore size distribution in porous materials., pycnometer, multipycnometer
Gas sorption
gas sorption, gas sorption analyzer, gas
sorption isotherm, gas sorption analysis, gas sorption porosimetry, gas
sorption analyser, gas absorption unit, pycnometer, multipycnometer
true density
true density, true density definition, true
density of water, true density formula, true density vs bulk density, true
density measurement, true density of zinc, true density of sand, true density
of coal, pycnometer, multipycnometer
gas pycnometer
gas pycnometer density, gas pycnometer
price, gas pycnometer method, gas pycnometer equation, gas pycnometer porosity,
gas pycnometer Micromeritics, gas pycnometer astm, gas pycnometer theory, gas
pycnometer india, pycnometer, multipycnometer
coalbed
coalbed methane, coal bed methane
extraction, coalbed methane in india, coalbed methane development, coalbed
recovery, coalbed association of Alabama, coal beds, coalbed methane ourreach
program, pycnometer, multipycnometer
Gold APP Instruments, supplier for surface
area and porosity analyzer, BET surface analyzer, gas pycnometer helium true
density analyser, high pressure and temperature gas adsorption analyser--- for
methane and coalbed gas.